SIMBAD references

2014MNRAS.437..532M - Mon. Not. R. Astron. Soc., 437, 532-546 (2014/January-1)

Herschel SPIRE and PACS observations of the red supergiant VY CMa: analysis of the molecular line spectra.

MATSUURA M., YATES J.A., BARLOW M.J., SWINYARD B.M., ROYER P., CERNICHARO J., DECIN L., WESSON R., POLEHAMPTON E.T., BLOMMAERT J.A.D.L., GROENEWEGEN M.A.T., VAN DE STEENE G.C. and VAN HOOF P.A.M.

Abstract (from CDS):

We present an analysis of the far-infrared and submillimetre molecular emission-line spectrum of the luminous M-supergiant VY CMa, observed with the Spectral and Photometric Imaging Receiver (SPIRE) and Photodetector Array Camera and Spectrometer for Herschel spectrometers aboard the Herschel Space Observatory. Over 260 emission lines were detected in the 190-650µm SPIRE Fourier Transform Spectrometer spectra, with one-third of the observed lines being attributable to H2O. Other detected species include CO, 13CO, H_2^18O, SiO, HCN, SO, SO2, CS, H2S and NH3. Our model fits to the observed 12CO and 13CO line intensities yield a 12C/13C ratio of 5.6±1.8, consistent with measurements of this ratio for other M-supergiants, but significantly lower than previously estimated for VYCMa from observations of lower-J lines. The spectral line energy distribution for 20 SiO rotational lines shows two temperature components: a hot component at ∼ 1000K, which we attribute to the stellar atmosphere and inner wind, plus a cooler ∼ 200K component, which we attribute to an origin in the outer circumstellar envelope. We fit the line fluxes of 12CO, 13CO, H2O and SiO, using the smmol non-local thermodynamic equilibrium (LTE) line transfer code, with a mass-loss rate of 1.85x10–4M/yr between 9R* and 350R*. We also fit the observed line fluxes of 12CO, 13CO, H2O and SiO with smmol non-LTE line radiative transfer code, along with a mass-loss rate of 1.85x10–4M/yr. To fit the high rotational lines of CO and H2O, the model required a rather flat temperature distribution inside the dust condensation radius, attributed to the high H2O opacity. Beyond the dust condensation radius the gas temperature is fitted best by an r-0.5 radial dependence, consistent with the coolant lines becoming optically thin. Our H2O emission-line fits are consistent with an ortho:para ratio of 3 in the outflow.

Abstract Copyright: © 2013 The Authors Published by Oxford University Press on behalf of the Royal Astronomical Society (2013)

Journal keyword(s): radiative transfer - stars: individual: VY CMa - stars: mass-loss - ISM: molecules - infrared: stars - submillimetre: stars

VizieR on-line data: <Available at CDS (J/MNRAS/437/532): tablea2.dat tablea3.dat>

Simbad objects: 4

goto Full paper

goto View the references in ADS

To bookmark this query, right click on this link: simbad:2014MNRAS.437..532M and select 'bookmark this link' or equivalent in the popup menu